01 / Federal Opportunity Brief
Automated Ultrasound-Based, Super Intelligence (SI)-Enabled Fracture Detection
02 / Federal Buyer
Who is buying?
03 / Purchase
What is the government buying?
Automated Ultrasound-Based, Super Intelligence (SI)-Enabled Fracture Detection
The current notice is soliciting this requirement from eligible offerors.
Respondents must provide information about standalone, point-of-care, AI (super intelligence)-enabled ultrasound devices for automated fracture detection, including diagnostic capability and specific supporting details (device/diagnostic performance, performance data, TRL and development status, regulatory documentation, IFU, manufacturing overview, and supply-chain/production information). The evidence also includes interoperability and field/austere operating requirements plus minimum training burden and independent operation when network is unavailable.
The notice says BARDA will use responses for planning purposes and will not award a contract under this notice; no specific contracting vehicle is stated.
Not disclosed in the provided evidence. This SSN describes information requested from respondents, but does not describe any future order/work assignment mechanism.
04 / Contracting Requirements
How will this procurement work?
| Requirement | What the notice says | Source status |
|---|---|---|
| Eligibility | The SSN seeks information from both small business and other than small business concerns, and respondents must identify their business size status as either small business or other than small business under the NAICS code and size standard identified in the notice. | Confirmed |
| Contract ceiling | Not disclosed | Not Disclosed |
| Minimum guarantee | Not disclosed | Not Disclosed |
| Contract duration | Not disclosed | Not Disclosed |
| Foreign participation | Not disclosed | Not Disclosed |
| Proposal and award procedure | Submission instructions are stated (format and email addresses; no separate instructions beyond sending required information). The evidence does not provide detailed evaluation/scoring factors because this is a planning-only SSN; it is not an award solicitation. | Partially Confirmed |
| Staffing and security | Not disclosed in the provided evidence. No staffing plan or security/clearance requirements are included in the supplied text. | Not Disclosed |
Read the original SAM.gov description
The Center for Biomedical Advanced Research and Development Authority (BARDA) intends to use responses to this Sources Sought Notice (SSN) for planning purposes. BARDA will not award any contracts under this Notice, but rather seeks current and forecasted prices, inventories, capabilities, and other pertinent marketplace data. This Notice is issued by the Center for Biomedical Advanced Research and Development Authority (BARDA) to identify innovative medical countermeasure technologies to enable rapid triage of musculoskeletal injuries such as fractures and soft tissue injuries of extremities. This request is for information only and is intended to assess the current state of commercially available technologies and technologies nearing commercial availability that support automated ultrasound-based fracture detection using technologies commonly known as Artificial Intelligence (AI). Consistent with Executive Order 14434, “Inaugurating the Era of Super Intelligence,” AI- technologies are now referred to as Super Intelligence (SI) throughout this notice, including in the title and should be referred the same in the response. The Center for Biomedical Advanced Research and Development Authority (BARDA) intends to use responses to this Sources Sought Notice (SSN) to inform planning for the potential acquisition of ultrasound-based devices capable of capturing and displaying anatomical data. Potential acquisition and inventory approaches include device purchases or leases supported by vendor-managed inventory (VMI) arrangements. BARDA seeks information on technologies that could assist clinical care providers in visualizing or detecting musculoskeletal injuries, including fractures and soft tissue injuries, to support triage and initial treatment in emergency departments, urgent care centers, and field settings. These devices could also support continued evaluation and treatment in definitive orthopedic care settings, consistent with applicable regulatory authorizations and intended uses. The U.S. Department of Health and Human Services (HHS) leads Federal public health and medical preparedness and response efforts, including supporting the research, development, acquisition, and availability of medical countermeasures (MCMs). These efforts address the health consequences of chemical, biological, radiological, and nuclear (CBRN) threats, pandemic influenza, and emerging infectious diseases, including threats arising from deliberate, accidental, or naturally occurring events. This SSN supports planning for medical capabilities that could strengthen the Nation’s preparedness for and response to emergencies involving traumatic injuries. The Project BioShield Act of 2004 (Pub. L. No. 108-276) established authorities for procuring qualifying security countermeasures for the Strategic National Stockpile (SNS). The Pandemic and All-Hazards Preparedness Act of 2006 (Pub. L. No. 109-417) further strengthened the Nation’s medical countermeasure development and preparedness framework. The National Health Security Strategy 2023–2026 provides additional strategic context for strengthening preparedness, response, and recovery capabilities. Consistent with these preparedness objectives, this Sources Sought Notice seeks information on potential approaches to improve the availability and accessibility of relevant medical devices across health care settings. Approaches of interest include purchase, lease, vendor-managed inventory (VMI), and arrangements that combine access to devices with maintenance and readiness support. Information received will inform acquisition planning and assessment of these approaches, subject to applicable statutory authorities, acquisition requirements, and availability of funds. These documents represent the foundation for addressing the Nation’s CBRN MCM needs. Amongst the foundational documents referenced above, musculoskeletal injuries such as fractures resulting from nuclear blast explosions and structural collapse, as well as and other mass casualty events present significant challenges in both field and clinical settings which require prompt diagnosis for adjudication and triage of patients. Current standards of care rely heavily on radiography and CT imaging, which are often unavailable, delayed, or resource-constrained in austere environments, disaster response settings, or during patient surge conditions. Delayed or missed fracture diagnosis can worsen patient outcomes and burden downstream care. BARDA is seeking solutions that enhance the speed, accuracy, and accessibility of fracture detection at the point of injury and point of care, without dependence on traditional imaging infrastructure. CAPABILITY STATEMENT/INFORMATION SOUGHT This Sources Sought Notice (SSN) seeks information from small business (SB) and other than small business (OTSB) concerns regarding their qualifications, experience, and capabilities to develop, manufacture, and deploy standalone, point-of-care, super intelligence (SI)-enabled ultrasound devices for fracture detection. Respondents shall provide only the information, data, and materials necessary to demonstrate their capabilities relevant to this notice. Responses shall include separate Technical Representation and Business Representation sections, as detailed below. Each section shall not exceed 10 single-sided pages, including all attachments, résumés, charts, and other supporting materials, and shall use 12-point Times New Roman font. Pages exceeding the limit for either section will not be reviewed. Respondents shall identify their business size status as either small business or other than small business under the NAICS code and corresponding size standard identified in this notice. Technical Representations Respondents shall provide the technical information requested by ASPR/BARDA in separately numbered sections, in the order listed below. For any section that does not apply, respondents shall retain the section number and heading, mark it “Not Applicable,” and briefly explain why it does not apply. Response Specification In response to this notice, clearly describe the capability and experience that meets the criteria specified in the subsequent categories. A template is provided for detailed and concise responses as related to the qualifying criteria. Additional supporting evidence, data, and information can be provided as attachments, not to exceed the 10-page limit per submission to this notice. All sponsors responding to this notice are required to provide the requested information on their products and capabilities by providing short responses, summarizing their device's diagnostic capability along with performance data, TRL and development status, regulatory documentation, product IFU, manufacturing overview, and supply-chain and production information. The narrative response to the templated prompts may include figures, schematics, diagrams, photographs, etc. and shall describe the proposed final product under consideration. Any proposed device must qualify against the following criteria (either work completed or demonstratable work in progress): Display and Diagnostic of Anatomy for Fracture Evaluation Capability Automated ultrasound imaging-based volumetric capture and display of detailed anatomy of different structures and providing bone detection/identification in areas such as wrist, ankles and others; and assist care providers to visualize clinically significant injuries such as fractures. Embedded ultrasound image processing information with appropriately trained Super Intelligence and machine learning (SI/ML) models to assist in image acquisition and segmentation for data interpretation with predefined sensitivity/specificity performance, which has been reviewed and adjudicated in FDA submissions for 510k clearance process. Models must be rigorously tested/validated against independent datasets separate from their training and their performance must improve upon that of human imaging experts. Capability either established or under development to distinguish different degrees / types of fracture and severity where it is deemed clinically appropriate, presence of edema or soft-tissue injuries. Capability to reconstruct and render 3D-rotatable models/ cross-sectional data review based on the captured ultrasound volumetric visualization of the bone and render the detection of injury and/or anatomy of the investigational areas for clinician adjudication. Use of color overlays for various anatomies and layers is ideal Performance comparison data against standard established technologies such as X-ray radiographic images or CT images. Desirable Device Design and Portability Characteristics Standalone, point-of-care form factor with integrated SI-processing. Units to be durable/ruggedized for field and disaster-response conditions Self-contained (e.g. all supplies and imaging media/gels sprays/wipes) all in a single portable unit which if required is field-deployable based on weight and size Battery life and power requirements suitable for use even under austere environments Ability to export and save data and link to EHR-systems within hospitals to enable billing and reimbursement. Interoperability with EHR or existing triage/documentation systems Use-Case Flexibility Operable in both field/austere environments and general clinical/hospital settings Minimal training burden for non-specialist operators (e.g., combat medics, first responders, general clinical technicians) Functions independently when a reliable network connectivity is unavailable Compatible with hospital ED workflows in rural and urban settings, use in urgent care centers and compatible with mass casualty triage workflows Development Status: Clinical and Regulatory Maturity Summary of advanced development pathway including various testing and validation performed; preclinical, clinical testing (MRMC, human factors) as well as bench testing. Regulatory Status: Pathway for product clearance/ approval as envisioned. Support this with a summary of pre-submission, FDA breakthrough designation efforts whether received or not, ongoing questions pending with FDA and/or feedback received. Any relevant work conducted under Department of War (DoW) or other federal agency Key technical risks identified, and mitigation plans Scalability and Manufacturing and Supply Chain Management / Resilience U.S. domestic maximum manufacturing capability and inventory management and warehousing strategy An established manufacturing process which covers required quality and ISO systems for GMP manufacture using reproducible, scalable processes with relevant operational certification from FDA and other regulatory bodies as a result of successful audits and accreditations. Strategy to establish supply chain resilience for all hardware and electronic components, sensors, transducers etc. critical for manufacture of the product. Cyber security and data storage and management security standards and certifications. List capability and testing for handling of sensitive patient PII and health information security and safeguards and transfer to other required systems such as electronic health records. Indicated Population and Use Cases Broad applicability across adult and pediatric patient populations Applicable to blast injuries, blunt trauma, structural collapse, and other mass casualty fracture presentations. Demonstrated or anticipated performance across a range of fracture types and anatomical locations. Response Format, Transmission, and Closing Date Respondents shall submit declarations of capability and all supporting information, data, and materials in Microsoft Office® or Adobe® Acrobat® format via email to Justin.Moore@hhs.gov and Richard.hall@hhs.gov. Responses must be received no later than 1:00 p.m. Eastern Time (ET) on November 18, 2026. All questions, comments, or concerns regarding this notice shall be submitted in writing to the same email address.
05 / Historical Spending Trend
How has spending on the selected comparable contracts changed?
The same closed fiscal-year window and the same complete comparable-contract set are used throughout this Brief. Net obligations total $700.0K across 2 fiscal years.

| Fiscal year | Comparable obligations | Actions | Vendors |
|---|---|---|---|
| FY 2020 | $700.0K | 1 | 1 |
| FY 2021 | $0 | 1 | 1 |
06 / Related Historical Awards
Which contracts support the comparison?
No direct contract reference was found. 1 broad match is shown as supporting context.

| Contract | Vendor | Latest activity | Office | NAICS / PSC | Match | Obligations | Actions |
|---|---|---|---|---|---|---|---|
| 75A50120C00151 | 98POINT6 INC. | Feb 3, 2021 | BARDA - ASPR / DAAPPO / BARDA DCMA | 541715 / AN13 | Broad match Buyer and requirement-language evidence | $700.0K | 2 |
07 / Contractor Evidence
Which contractors have performed related work?
Historical contractors are ranked by direct procurement-family evidence and comparable contract activity. The table distinguishes connected holders from broader performers without identifying unverified bidders.
No directly connected predecessor was identified. The companies below are historical performers selected from the comparable contract set; none is identified as a bidder.

| Company | Evidence | Fit | Why included | Contracts | Actions | Obligations | Latest activity | Links |
|---|---|---|---|---|---|---|---|---|
| 98POINT6 INC. UEI VUJ2VK8B9YZ4 · CAGE 89U17 | Broad historical performer Historical performer | Moderate | Comparable buyer and requirement history | 1 | 2 | $700.0K | Feb 3, 2021 | GETWAB profile |
08 / Competitive Landscape
How was comparable work competed?
Competition treatment is calculated from exactly the same closed-period contract set used in Sections 5–7. It describes historical actions, not the outcome of this solicitation.

| FPDS treatment | Code | Actions | Obligations | Share |
|---|---|---|---|---|
| Full and open competition | A | 2 | $700.0K | 100.0% |
09 / Procurement History
How was this opportunity published and updated?
One SAM.gov notice record was resolved for this procurement family.
| Notice | Type | Posted | Response deadline | Status | Official source |
|---|---|---|---|---|---|
| BARDA-FY27-10192026 Current Brief record Automated Ultrasound-Based, Super Intelligence (SI)-Enabled Fracture Detection | Sources Sought | Oct 20, 2026 | Nov 18, 2026 1:00 PM GMT-0500 | Active | View on SAM.gov |
10 / NAICS and PSC Market Context
How large is the selected comparable market?
Classification codes organize the evidence; they do not prove that every contract in the broader NAICS or PSC market matches this requirement.
11 / Capture Signals and Risks
What should be validated before committing capture resources?
Capture signals separate verified procurement-family evidence from unresolved requirements and market-only indicators.
Direct procurement-family evidence
No direct award record found
Buyer proximity
1 comparable record(s) share the contracting office
Eligibility
No Set aside used
Unresolved requirement fields
6
12 / Who Should Pursue
When does this opportunity fit?
- Your team can demonstrate recent, relevant delivery in Automated Ultrasound-Based, Super Intelligence (SI)-Enabled Fracture Detection.
- Your company can document the stated eligibility conditions: The SSN seeks information from both small business and other than small business concerns, and respondents must identify their business size status as either small business or other than small business under the NAICS code and size standard identified in the notice.
- You can perform under the stated acquisition model: The notice says BARDA will use responses for planning purposes and will not award a contract under this notice; no specific contracting vehicle is stated.
- You can show credible past performance for BARDA - ASPR / DAAPPO / BARDA DCMA or a closely related federal customer.
- Your technical scope fits, but you lack demonstrated history with BARDA - ASPR / DAAPPO / BARDA DCMA.
- You need a specialist teammate to close unresolved staffing, security, or detailed-scope requirements before committing.
- You cannot satisfy or verify the stated eligibility conditions: The SSN seeks information from both small business and other than small business concerns, and respondents must identify their business size status as either small business or other than small business under the NAICS code and size standard identified in the notice.
- Your delivery model cannot support the stated contract vehicle or order-based work structure.
- The unresolved requirements shown above cannot be validated before committing proposal resources.



